CHQMB - PN:LP777 LIQUIFIED PETROLEUM GAS(LPG)-PROPANE
- MSDS: CHQMB
- Manufacturer: TURNER CO DIV OF CLEANWELD PRODUCTS CO
- Product Name: PN:LP777 LIQUIFIED PETROLEUM GAS(LPG)-PROPANE
- National Stock Number: 4940-01-144-6766
Product Identification
Product ID:PN:LP777 LIQUIFIED PETROLEUM GAS(LPG)-PROPANE
MSDS Date:07/01/1996
FSC:4940
NIIN:01-144-6766
MSDS Number: CHQMB
Responsible Party
SYCAMORE, IL 60178-2419
US
Emergency Phone: 815-895-4545
Info Phone: 815-895-4545
Cage: 61112
Contractor
Telephone: 815-895-4545
Cage: 61112
Ingredients
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: >90%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT; 9596
PROPYLENE (PROPENE) (SARA 313)
CAS: 115-07-1
RTECS: UC6740000
Fraction By Weight: <5%
ACGIH TLV: ASPHYXIANT; 9596
BUTANE
CAS: 106-97-8
RTECS: EJ4200000
Fraction By Weight: <2.5%
OSHA PEL 800 PPM
ACGIH TLV: 800 PPM; 9596
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN:CONTACT W/LIQ MAY CAUSE
FROSTBITE.INHAL:HUMANS EXPO TO 10000PPM NBUTANE FOR 10MINS EXHIBITE
DROWS BUT NO OTHER EVIDENCE OF SYSTEMIC EFFECTS.ACCUMULATION OF HI
CONCEN MAY CAUSE CNS DEPRESS OR DISPLACE ATM OXY CAUSING
SUFFOCATION.INGST:NOT ANTICIPATED AS PROD IS GAS.
Explanation of Carcinogenicity:PER
MSDS:CARCINOGENICITY:NTP/OSHA/IARC:NO.
Effects of Overexposure:INGEST:GAS.SKIN;PROPANE W/ISOBUTANE IN
DEODERANT/ANTIPERSPIRANT PROD(65-71% WT)WAS NOT SHOWN TO CAUSE SKIN
IRRIT IN HUMAN VOLUNT(AERO APPLIED 2X DAILY,12WKS).EYE:NO
DATA.INHAL:NO SUBJ PHYS RESPONSES,E XPO RELATED CARDIAC ABNORM/PULM
FUNCTION ABNOR REPORTED IN VOLUNT EXPO TO
PROPANE.NUMB,HEAD,VOMIT,CHILL FEEL GAS ESCAPED
Medical Cond Aggravated by Exposure:NONE KNOWN. TARGET
ORGANS:RESPIRATORY SYSTEM, CNS.
First Aid
First Aid:EYE:GAS-FLUSH W/LUKEWARM H2O FOR 15MINS.IRIT DVLPS SEEK MED
ATTN.LIQ-OPEN EYES WIDE TO ALLOW LIQ TO EVAPORATE.SEEK IMMED MED
ATN.SKIN:GAS-FLUSH W/LUKEWARM H2O FOR 15MINS.IRRIT PERSISTS SEEK
MED ATTN.L IQ-FROSTBITE OCURS SEEK MED ATTN.INHAL:REMOVE TO FRESH
AIR.BREATH DIFF ADMIN OXY;BREATH STOP GIVE ART RESP.SEEK MED
ATTN.OTHER:NOT ANTICIPATED.IF CRYOGENIC LIQ ACCIDENTALLY INGEST
SEEK IMMED MED ATTN.
Fire Fighting
Flash Point Method:CC
Flash Point:-155F,-104C
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:2 PROPANE
Upper Limits:9.5 PROPANE
Extinguishing Media:SM-DRY CHEM,FOAM,CO2.LG-H2O SPARY/FOG.STOP GAS FLOW
BEF ATTEMPT EXTI.CONT GAS FLOW CREATE EXPLO GAS/AIR MIX-IGN MORE
HAZ
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR NIOSH/MSAH-APPROV
SELF-CONTAINED BREATHING APPARATUS OPERATED IN POSITIVE PRESSURE
MODE & FULL TURNOUT GEAR OR BUNKER GEAR.
Unusual Fire/Explosion Hazard:THERM DECOMPO PROD CARBON OXIDES.HIGHLY
FLAMM/EXPLO.VAP TRAVEL TO IGN SOURCE,FLASHBACK.VAP HEAVIER THAN
AIR,MAY TEND TO ACCUMULATE IN LOWLYING AREAS.EXPLO(SUPP)
Accidental Release
Spill Release Procedures:EXT/REMOVE ALL IGN SOURCES.REMOVE CNTNR TO
OUTSIDE IF POSSIBLE;NOT POSSIBLE ISOLATE HAZ AREA-DENY ENTRY TO
UNAUTHORIZED/UNPROT PERSONNEL.VAP TRAVEL CONSIDERABLE DISTANCE TO
IGN SOURC-FLASHBACK.VENTI E NCLSD AREAS.FOUSH LG SPILLS
W/H2O.CLEANUP H2O(SUP)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:BOND/GROUND ALL LINES/EQPMT ASOSC
W/PROD SYS.ELECT EQPMT SHOULD BE NONSPARK/EXPLO PROOF.USE ONLY
W/ADEQU VENTI.EMPTY CNTNR MAY CONTAIN FLAMM RESIDUE.
Other Precautions:DISPO/HNDL EMPTY CNTNR ACCORDINGLY.PROT FRM PHYS
DMG.DONT DRAG/SLIDE/ROLL CYL.USE SUITABLE HAND TRUCK.STORE URIGHT
IN COOL DRY WELL VENTI AREA AWAY FRM EMERG EXIST,OTHER FLAMM,HEAVY
TRAVEL AREA.CYL TE MPS SHOULDNY EXCEED 120F.1ST IN 1ST OUT.
Exposure Controls
Respiratory Protection:UNDER NORMAL CONDITOINS (AMBIENT TEMPERATURE AND
PRESSURE) AND USE NONE REQUIRED.
Ventilation:LOC EXHA VENTI AS NECESSARY-PREVENT CONC FRM EXCEED EXPO
GUIDELINES/PREVENT EXPLO CONC BUILDUP.ELECT EPQMT SUIT FLAM ATM
Protective Gloves:NROPRENE,PLASTIC,RUBBER GLOVES
Eye Protection:SAF GOGG/GLASSES,FCSHIELD FOR CRYOGEN LQ
Other Protective Equipment:EMERG SHOWER/EYEWASH STATIONS.AIR SMPL FOR
BUTANE-COCNUT CHARCOAL SOBENT TUBE,FOR PROPANE-ANASORB CMS.
Work Hygienic Practices:DONT SMOKE IN WORK/STORAGE AREA;SIGNS SHOULD BE
POSED.CHANGE CONTAM CLOTH IMMED-FIRE/EXPLO HAZ.WASH HANDS AFT
HNDLG.
Supplemental Safety and Health
FIRE/EXPLO:HAZ INDOORS,OUTDOORS,CONF AREAS.CYL MAY EXPLO IF EXPO TO
HEAT/FLAME.FIRE PRESENT IN STORAGE AREA,DONT ENTER.CONT TO COOL
FLAME EXPO CNTNR W/H2O TIL WELL AFT FLAMES HAVE BEEN EXTINGUISHED.
S PILL:RUNOFF TO SEWERS MAY CAUSE FIRE/EXPLO.DONT REENTER TIL PROD
SUFFIC DISPERSED.CLEANUP PERSON WEAR APPRO PPE,RESP PRO
Chemical Properties
HCC:G2
Boiling Pt:B.P. Text:-44F,-42C
Melt/Freeze Pt:M.P/F.P Text:305F,152C
Decomp Temp:Decomp Text:NP
Vapor Pres:300PSIG
Vapor Density:1.52
Spec Gravity:0.51 LIQ
pH:NA
Viscosity:GAS
Evaporation Rate & Reference:NP
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS GAS, PUNGENT(MERCAPTAN ADDITIVE)ODOR
Percent Volatiles by Volume:GAS
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.PROPANE AND CHLORINE DIOXIDE CAN EXPLODE ON CONTACT.
Stability Condition to Avoid:DONT HEAT CYL BY ANY MEANS.DONT CARRY IN
ENCLSD SPACE(CAR TRUCK,VAN,STATION WAGON)-ACCIDENTAL
RELEASE-ASPHYX,FIRE,EXPLO.
Hazardous Decomposition Products:THERMAL DECOMPOSITION WILL PRODUCE
CARBON OXIDES.
Disposal
Waste Disposal Methods:VOLAT TO ATM EXPECT TO BE DOMINANT FATE
PROCESS.IN ATM RX W/PHOTOCHEM PROD HYDROXYL RADICALS W/AVG ATM
1/2LIVES 6/12 DAYS RESP.DISPO OF IAW APPLIC LOC/STATE/FED
REGS.DISPO PER 40CFR261,262.CAA TQ=1000 0LBS.SARA 313 CHEMS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.